Dial Service Parameters
114062 Rev. B A-71
Parameter: Circuit State Set
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List > Services > Frame Relay
Demand Service List > PVCs > Add > FR PVC List for Demand Service
<service no.>
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface > Services > Frame
Relay Backup Service List > PVCs > Add > Frame Relay Backup PVC List
Default: Active
Options: Invalid
| Active | Inactive
Function: Specifies the state of the PVC.
Instructions: Set to Active to indicate to a Frame Relay switch that the PVC is available for
use. Set to Inactive to indicate that the PVC is configured, but not available for
use, for example, before your switch provider actually activates the PVC.
Choose Invalid if the PVC is configured, but the switch is unaware of it.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.7
Parameter: Multicast
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List > Services > Frame Relay
Demand Service List > PVCs > Add > FR PVC List for Demand Service
<service no.>
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface > Services > Frame
Relay Backup Service List > PVCs > Add > Frame Relay Backup PVC List
Default: Unicast
Options: Unicast
| Multicast
Function: Indicates whether this PVC is multicast or unicast.
Instructions: Set to unicast or multicast according to PVC type, as the Frame Relay switch
provider instructs.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.19