Avaya Configuring Dial Services Manual de usuario Pagina 282

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 281
Configuring Dial Services
A-12 114062 Rev. B
V.34 Modem Parameters
These parameters are available only for the ARN using the V.34 Modem Adapter
Module.
Parameter: Expert Config
Path: COM Connector > Edit Modem > Edit V.34 Modem Interface Parameters
Default: Disabled
Options: Enabled | Disabled
Function: Enables or disables configuration of the Modem Config String parameter.
Instructions: To use only the factory default configuration, leave this set to Disabled. Set to
Enabled to enter an AT command string in the Modem Config String field.
MIB Object ID: 99999.1400.211
Parameter: Modem Config String
Path: COM Connector > Edit Modem > Edit V.34 Modem Interface Parameters
Default: None
Options: An ASCII text string of 3 to 34 characters.
Function: Specifies a modem initialization string to be sent to the modem after the default,
factory-configured command string. Commands in this string take precedence
over commands in the factory default string
(
AT&M2&Q2&D0&S1&R0S0=0M1L2T).
Instructions: Enter an AT command string. Refer to Appendix E for a list of AT commands.
Note that entering an invalid command string could disable the modem. Site
Manager can verify AT command string changes only when in dynamic mode.
MIB Object ID: 1.3.6.1.4.1.18.3.4.29.1.1.9