Configuring Dial Services
A-48 114062 Rev. B
Parameter: Failback Time (min.)
Path: Demand Circuits only: Dialup > Demand Circuits > Demand Pools> PPP or
FR Circuits > PPP or FR Demand Circuits > Schedule > Circuit Time of Day
Schedule or Pool Availability List > Add > Circuit Time of Day Schedule
Default: 0
Range: 0 to 1439 minutes
Function: For PPP standby circuits only, this parameter indicates the amount of time the
router waits before deactivating the standby circuit and returning to a
recovered primary circuit. This option is available only if the Standby Mode
parameter is set to Hot Standby, the Standby Failback Mode parameter is set
to None, and you have selected a primary circuit for the Standby Primary
Circuit parameter.
Instructions: Enter the amount of time, in minutes, that the router should wait before
returning to the primary circuit for data transmission. Be sure to consider how
much time it takes to ensure that the primary circuit is stable.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.11.1.10