Dial Service Parameters
114062 Rev. B A-63
Parameter: Address Length
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: Two Byte
Options: Two Byte
| Three Byte | Four Byte
Function: Specifies the length of the Frame Relay address field.
The length of this field determines the range of valid numbers for the DLCI
number set in the Frame Relay PVC List window. Refer to the Configuring
Frame Relay Services for more information.
Instructions: Select the address length for the address field. This must match what the
network specifies.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.9
Parameter: Polling Interval
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: 10 seconds
Range: 5 to 30 seconds
Function: Specifies the interval between status inquiry messages that the router transmits.
Status inquiry messages cause a network response in the form of a link Integrity
verification message or full status message. Successful completion of the
request/response “handshake” verifies the status of the router/Frame Relay
network link.
Instructions: We recommend that you accept the default value, 10 seconds. If the default
value does not match what the network requests, enter a value that is appropriate
for your network in the range of 5 to 30 seconds. Polling Interval does not
function if you set Mgmnt Type to DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.10