Dial-up resources configuration 97
Nortel Business Communications Manager 5.0
Configuration — System
NN40170-501 02.04 Standard
September 2009
Copyright © 2009, Nortel Networks
Variable definitions
Modem interface management
Attention: Modem interface management is not applicable for BCM50.
BCM supports one V.34 modem connection to, and from, the BCM450.
Modem interface management navigation
• Adding a modem interface (page 97)
• Enabling a modem interface (page 98)
• Disabling a modem interface (page 98)
• Deleting a modem interface (page 99)
Adding a modem interface
Use this procedure to add a modem interface.
Variable Value
PPP Settings
IdleTime out (s) The interval after which the ISDN interface disconnects when there is
no traffic.
Default: 90 seconds
<0-36000>
Note: A value of 0 makes the connection persistent.
Maximum receive unit The maximum size of the packets that can be received. <128_1500>
Default: 1500
Maximum transmission unit The maximum size of the packets that can be received.
<128_1500> Default: 1500
IP header compression Enable or disable IP header compression.
Note: This feature must be enabled at both ends of the connection.
Default: enabled
Software compression Enable or disable software compression. When enabled, all dial-up
connections use BSD Scheme for compression.
Default: disabled
Access Settings
Authentication Select the authentication type for the link.
Default: CHAP
User Name Select the user name used for authenticating to the remote end.