Testing the main unit
If you have the digital station MBM installed in the main unit, use the following
test to ensure the BCM main unit is operating properly.
Attention: As BCM50 does not have MBM in the core system, it should be
added to BCM50 with keycode-enabled expansion cabinet.
Procedure steps
Step Action
1 Go to an extension that is connected to a digital station MBM on the main
unit.
2 Check for a dial tone.
3 Use this extension to make a call to another extension on the system.
4 If this system has an expansion unit with a media bay module (MBM) that
supports extensions, repeat step 1 to step 4 for an extension connected to
the expansion unit.
5 Go to an extension that has access to one of the lines on the main unit.
6 Select the line or line pool to which the line belongs.
7 Check for a dial tone.
8 Make a call using the line or line pool.
9 If this system has an expansion unit with an MBM that supports lines, repeat
step 5 to step 8 with an extension that can access one of the lines
connected to the expansion unit.