138 BCM 5.0 expansion unit testing
Nortel Business Communications Manager 5.0
Configuration — System
NN40170-501 02.04 Standard
September 2009
Copyright © 2009, Nortel Networks
BCM 5.0 expansion unit testing navigation
Testing the expansion unit or expansion cabinet for BCM 5.0 (page 138)
Troubleshooting the expansion unit for BCM50 (page 139)
Troubleshooting the expansion cabinet for BCM450 (page 138)
Testing the expansion unit or expansion cabinet for BCM 5.0
Use the following test to ensure the BCM expansion unit is operating properly.
Procedure steps
Step Action
1 Make sure that the BCM system is fully booted.
2 Check the power and status LEDs on the MBMs that are inserted in the
expansion unit.
Both LEDs must be solid green. If either LED is not solid green, a
problem exists with the MBM or the expansion unit.
3 If the expansion unit has an MBM that supports extensions, go to an
extension that is connected to the MBM.
4 Check for a dial tone.
5 Use this extension to make a call to another extension on the system.
6 If the expansion unit has an MBM that supports lines, go to an
extension that accesses to one of the lines on the MBM.
7 Select the line or line pool to which the line belongs.
8 Check for a dial tone.
9 Make a call using the line or line pool.
--End--
Troubleshooting the expansion cabinet for BCM450
Troubleshoot the BCM450 expansion cabinet if the expansion unit is not
functioning properly.
Prerequisites
Test the BCM450 expansion cabinet for proper functionality. For more
information, see Testing the expansion unit or expansion cabinet for BCM
5.0 (page 138).