158 System parameters reference
Nortel Business Communications Manager 5.0
Configuration — System
NN40170-501 02.04 Standard
September 2009
Copyright © 2009, Nortel Networks
Configuring digital and analog loop module parameters
Module mode: The mode for the type of line being supported (DS/CLID,
Global, Legacy).
Disconnect Timer: Enter the time delay for disconnect supervision for lines
supplying supervised external lines. This setting must match the CO setting.
T1 parameters
CO fail T1 PRI
Specify a carrier failure standard (T1A-5474, TR62411)
Interface
levels
ISDN, PSTN T1 PRI
Define a loss plan setting.
Framing ESF, SF T1 PRI
Select the framing format used by your T1 or PRI service provider: Extended Superframe
(ESF) or Superframe (SF). Contact your T1 or PRI service provider for the proper setting.
(SF or Superframe is sometimes known as D4.)
Line coding B8ZS, AMI T1 PRI
Define the encoding signals on a T1 line. Select the standard used by your T1 service
provider. Contact your T1 service provider for the proper setting.
Internal
CSU
<check box> T1 PRI
Turn the internal T1 channel service unit (CSU) on or off.
CSU line
build
0, 7.5, or 15 dB T1 PRI
Set the gain level of the transmitted signal. This setting appears only if the Internal CSU
is Enabled.
DSX1 build 000-100, 100-200,
200-300, 300-400,
400-500, 500-600,
or 600-700 feet
T1 PRI
Set the distance between BCM 5.0 and an external channel service unit. This setting
appears only if the Internal CSU is Disabled. Contact your service provider for the proper
settings.
CRC4 <check box> E1
PRI
Ensure this is enabled or disabled to match the service provider Cyclic Redundancy
Check (CRC4) setting for the trunk.
Attribute Value Module/line type