88 BCM 5.0 trunk module configuration
Nortel Business Communications Manager 5.0
Configuration — System
NN40170-501 02.04 Standard
September 2009
Copyright © 2009, Nortel Networks
Variable definitions
Provisioning module lines and loops
Configure the module lines and loops for your BCM system.
Prerequisites
Configure the trunk module parameters. For more information, see
Configuring the trunk module parameters (page 86).
Procedure steps
Step Action
1 Select Configuration > Resources > Telephony Resources.
2 On the Modules panel, click the trunk module entry that you want to view.
The panel that appears depends on the type of module that is selected.
3 Provision the lines, virtual channels, and loops for your module.
The Provision Line tab panel is used for all trunks except DPNSS and
BRI loops.
The DPNSS module shows the Provision Virtual Channels tab panel.
BRI loops require an extra step, so the Provision Loops tab panel
appears after a BRI module is selected.
--End--
Variable definitions
Variable Value
Service Type Foreign Exchange Define the applicable services for the protocol defined on the
Module record.
Translation Mode Define how the incoming digits get mapped to line numbers
(target lines or DISA/AUTO DNs) within the system.
Translate All Calls To Enter the appropriate information for the mode chosen.
Variable Value
Provision Lines tab
Line <line number> This is a list of the lines assigned to the module.
Provisioned <check box> If the check box is selected beside a line, that line is available for
call traffic.