Configuring Dial Services
A-20 114062 Rev. A
After entering a backup pool ID, the Backup Lines Definition window appears.
Click on the ISDN1 connector. Site Manager automatically displays the ISDN
Switch Configuration window.
Path: Backup Lines Definition window > ISDN Switch Configuration window
The ISDN Logical Lines window appears after the ISDN Switch Configuration
window. Accept the default parameter settings.
Backup Circuit Configuration
Once the backup pool is set, configure backup circuits. Select Dialup > Backup
Circuits from the main menu bar.
Remember that you do not specifically configure a backup circuit. You are
actually designating a leased circuit as a primary circuit. If this circuit fails, the
router provides a backup circuit that adopts the configuration of the primary.
Path: Primary Circuit Definition window (highlight S131 or S12 -- click on
Cct Type) > Circuit Options window
Table A-26. Backup Pools
Parameter Name
Router 1
(S131)
Router 2
(S12)
Pool ID 1 1
Table A-27. Switch Configuration Parameters
Parameter Name
Router 1
(S131)
Router 2
(S12)
Switch Type NI1 NI1