Configuring Dial Services
8-12
114062 Rev. A
Parameter: UpTime Term. Reset
Default: 60 minutes
Range: 1 to 999999 minutes
Function: Determines the amount of time the router waits before making the
demand circuit available again after an uptime termination (Max UpT
ime
Termination parameter). The circuit is not established at this point, but the
next time the router receives data, the circuit is now available and the
router can activate it.
The router invokes this timer only after an invoking the UpTime
Termination function.
Instructions: Enter the time period before the router waits before making the circuit
available again. You must enter a value for this parameter if you
configured the Max UpTime Termination parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.34
Parameter: Circuit Name
Default: None
Options: Any valid demand circuit name
Function: Identifies the name of the demand circuit.
Instructions: Site Manager fills in this name based on the available circuit names. To
modify this parameter, enter a new name to modify and click on Apply.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.3.1.3
Parameter: Minimum Call Duration
Default: 60 seconds
Options: 10 to 2,147,483,647
Function: Specifies the minimum amount of time that the connection remains active
regardless of whether there is data traffic.
Instructions: Enter the minimum amount of time the connection should remain active.
For dial optimized routing circuits, this timer should be set long enough to
send all routing updates to the remote nodes in the network.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.45
Comentarios a estos manuales