Configuring Dial Services
9-38 114062 Rev. A
Parameter: End Time
Default: 2359
Range: 0 to 2359
Function: Specifies the time that the backup line is no longer available for the
primary line. The router uses this value along with the Start Time
parameter.
Instructions: Enter an hour of the day, using the 24-hour-system of expressing time.
For example, to deactivate the circuit at 10:00 p.m., enter 2200.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.11.1.6
Deleting Backup Circuits
To delete a backup circuit, you change the primary circuit back to a normal circuit
as follows:
1. Select Dialup > Backup Circuits > Frame Relay.
Site Manager displays the Primary Circuit Definition window (refer to
Figure 9-5).
2. Click on Intf. Type.
Site Manager displays the Circuit Options window (refer to Figure
9-4).
3. Change the Circuit Type parameter to Normal. Click on OK.
Site Manager asks you to confirm your change, then removes the backup
circuits, and no longer treats this circuit as a primary circuit.
4. Click on Done to return to the Configuration Manager window.