Configuring Backup Circuits
114062 Rev. A
9-19
Parameter: Max UpTime Termination
Default: Disabled
Options: Enabled
|
Disabled
Function: Automatically brings down the circuit if the call reaches the maximum
time that you specify in the Maximum Up Time parameter. If the router
receives data after the circuit is down, the router does not establish a
backup connection.
Instructions: Enter Enable if you want the circuit to terminate upon reaching the
maximum time limit for the call.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.33
Parameter: UpTime Term. Reset
Default: 60 minutes
Range: 0 to 999999 minutes
Function: Determines the amount of time the router waits before making the backup
circuit available again after an uptime termination (Max UpT
ime
Termination parameter). The circuit is not active at this point, but the next
time the router receives data, the circuit is now available and the router
can activate it.
The router invokes this timer only after invoking the UpTime Termination
function.
Instructions: Enter the time period before the router waits before making the circuit
available again. You must enter a value for this parameter if you
configured the Max UpTime Termination parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.34