86 Chapter 2 General CLI commands
212160-B
The system resets and opens to the BPS2000 banner. Refer to Accessing the
CLI on page 35 to return to the CLI.
2 Enter
download [address <ip>] diag bps2000diags.bin.
The system resets and opens to the BPS2000 banner. Refer to Accessing the
CLI on page 35 to return to the CLI.
However, if you are currently using software version 1.0, 1.0.1, or 1.1, you must
upgrade to software version 1.1.1 before upgrading to version 2.0.
Upgrading software in a Hybrid stack
The physical order of the units and the unit numbering in the Hybrid stack does
not affect the upgrading process at all. In addition, the cabling order regarding
upstream/downstream neighbors does not affect the process.
Before you attempt to download new software (or upgrade software) to a Hybrid
(mixed) stack, you must ensure that the Interoperability Software Version
Numbers (ISVN) are identical. That is, the ISVN number for the BayStack 450
switch and BayStack 410 switch must have the same ISVN as the BPS 2000. If the
ISVNs are not the same, the stack does not operate. The ISVNs and the
accompanying software release are:
ISVN 1
BayStack 410 or Bay Stack 450version 3.1
BPS 2000versions 1.0 and 1.0.1
ISVN 2
BayStack 410 or BayStack 450versions 4.0 and 4.1
BPS 2000versions 1.1, 1.1.1, 1.2, and 2.0
This section describe the steps for the following software upgrades:
Upgrading software when ISVN is 2, next
Upgrading software when ISVN is 1 on page 87