To specify the severity level for event messages, complete the tasks in the
following table.
Specifying Threshold Units
You can specify the units used to determine whether a variable has exceeded a
threshold.
• To generate a threshold event when the variable’s rate of change per second
reaches one of the thresholds, set the Threshold Units parameter to
Persecond.
• To generate a threshold event when the value of the variable reaches one of the
three thresholds, set the Threshold Units parameter to Absolute.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
Global Protocols
. The Global Protocols menu opens.
3. Choose
Thresholds
. The Thresholds menu opens.
4. Choose
Thresholds
. The Thresholds Interface Lists window
opens.
5. Set the following parameters:
• Threshold Low Event Level
• Threshold Medium Event Level
• Threshold High Event Level
Click on
Help
or see the parameter
descriptions beginning on page A-10.
6. Click on
Done
. You return to the Configuration Manager
window.