Facility Busy Indication
You can use Facility Busy Indication to display the idle or busy condition of phones,
trunks, or paging zones.
To use this feature you need to add facility busy indication buttons to your phone. Label
the facility busy buttons as "Busy" followed by the number or name of the facility being
monitored.
If the green light associated with the Facility Busy Indication button stays lit for a long
time, the facility may have a problem.
Facility Test Calls
You can use Facility Test Calls to place test calls to specific trunks or phones. Because
this feature bypasses the regular system traffic, it is very helpful in finding noisy lines and
other problems. However, this feature can be easily misused by outside parties. Disable
this feature when you are not using it.
Security Alert:
Whenever you use this feature, enable the feature access code only for the tests
you want to make. Be sure to immediately remove the access code when you are
through testing because leaving this feature enabled can leave you open to
security breaches.
To place a test call to a trunk or touch-tone phone:
1 Using GEDI, enable a feature access code for Facility Test Call.
2 At your phone, dial the feature access code for Facility Test Call. Listen for dial tone.
3 Dial the 6- or 7-digit port address.
Tip
If you have problems with this step, try dialing the port address without the first
zero in the cabinet number.
You hear a tone and see a display. The following table describes what the tone and
display indicate and how to respond.
tone
frequency
pattern
(secon
ds)
status of
extension
next step
dial combined
350 Hz
+440 Hz
continuo
us
connected Go to Step 4
reorde
r
combined
480 Hz
+620 Hz
.25 on
.25 off
repeate
d
busy release the call
interce
pt
440 Hz
alternating
620 Hz
.25 on
.25 on
repeate
d
No access release the call