Avaya Site Administration Reference
139
Alarm logs
Alarms are classified as major, minor, or warning, depending the degree of severity and
the effect on the voice system.
warning level and
description
reported in
INADS?
reported
to
console?
take this
action
major
Critical service degradation
Y Y
(occurs
after 4
attempts to
call INADS)
Immediate
attention
Minor
Some service degradation,
but system is operable,
usually limited to a few
trunks or stations or a
single feature
Y Y
(occurs
after 4
attempts to
call INADS)
Check to
see what
service is
affected
Warning
Failure that causes no
significant service
degradation
Note:
DS1 off board faults (error
type 138) generate warning
alarms only, indicating a
customer network problem.
In this case, warning alarms
can cause critical service
degradation
N
(INADS
can receive
some
downgrade
d warning
alarms)
N
Monitor the
situation;
check for
service or
equipment
interruption
or failure
outside the
voice
system
Alarms are further classified as:
on-board problems originate within the circuitry of the alarmed circuit pack
off-board problems originate in a process or component that is external to the circuit
pack
Comentarios a estos manuales