Avaya Site Administration Reference
143
Remove unused circuit packs
Occasionally, a company upgrades phones from the 7000-series analog model to the
8400-series digital phones. The upgrade process is to:
1 Remove the analog line and trunk administration
2 Remove the old analog equipment
3 Rewire the workplace for the new digital phones and jacks
4 Administer the new digital phones and circuit packs
If the analog circuit packs remain physically plugged into the system and are still
administered as circuit packs (even though the administration is removed in Step
1above), the system generates errors. This stops when you remove the administration
(change circuit-pack UUCSS) for this unused circuit pack.
DS1 administration
Depending on whether a DS1 circuit pack is present and whether its ports are assigned
or not, the system reports faults according to the following table:
circuit
pack
presen
t?
circuit
pack
administer
ed?
ports
administer
ed?
alar
m
level
action
N Y N
warn
ing
Replace and latch the board in its
assigned slot.
Remove the trunk and DS1
administration (change circuit-pack
UUCSS), leaving the circuit pack in
its assigned slot.
N Y Y
mino
r
Replace and latch the board in its
assigned slot.
Administer one or more ports
(change circuit-pack UUCSS),
leaving the circuit pack in its
assigned slot.
Y N N
varie
s
Remove the circuit pack from the
carrier.
Comentarios a estos manuales