Clearing an error
If an important component in your DEFINITY system fails, the DEFINITY software
records that "event" with code numbers in the DEFINITY error or alarm log. To interpret
the error codes and clear the error:
1 Look up the Maintenance Object (MO) (for example, DIG-LINE or PI-LINK) in the
DEFINITY ECS Maintenance books for your voice system.
2 Find the error type in the Hardware Error Type table for that MO.
To display the Hardware Error Table, see Viewing error logs.
3 Find the note associated with that error type for an explanation of the conditions that
generated the error.
4 Perform the recommended procedure to clear the error.
The recommended procedure may require you to test alarmed components. Be sure
to have test permissions enabled.
If any tests fail or abort, you will get an error code for the test.
5 Look up the test error code by MO in your DEFINITY ECS Maintenance books.
6 Find the numbered test listed in the test results.
7 Look for the correct combination of error code and test result in the numbered-test
tables.