Avaya Troubleshooting Routers Guía para resolver problemas Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 266
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
Troubleshooting Routers
5-4 117379-A Rev. A
5. Use the Events Manager or the Technician Interface to display the
attributes associated with the MIB objects in T
able 5-3.
6. Redisplay the MIB objects in Table 5-3 after 1 minute; then, compare the
values to determine which errors are currently occurring.
If applicable, see one of the following sections:
Dr
opped Frames
A
TM VC Mod Failed Message
Upper
-Layer Protocols Failing to Pass Packets
PVC Pr
oblems
a. The instance ID associated with this object is the line number.
b. There are no statistics available on the types of cells received and transmitted; the value is always
0.
Table 5-3. Second Set of ATM Interface MIB Objects to View
MIB Object Description Quick Get Path
wfAtmAlcDrvEntry Shows how much data the
link module is transmitting
wfLine >
wfAtmInterfaceGroup
>
wfAtmLinkModule >
wfAtmAlcDrvEntry
wfAtmAlcCopErrorEntry Shows physical errors
such as link delineation
errors
wfLine >
wfAtmInterfaceGroup
>
wfAtmLinkModule >
wfAtmAlcCopErrorEntry
wfAtmAlcCopDataPathEntry
ab
Shows the ATM
coprocessor buffer
utilization, the number of
cells received and
transmitted, and the
number of dropped
(clipped) frames
wfLine
>
wfAtmInterfaceGroup
>
wfAtmLinkModule
>
wfAtmAlcCopDataPathEntry
Vista de pagina 81