Troubleshooting Routers
3-20 117379-A Rev. A
Fault Message
If a software entity experiences a fault and fails to recover, do the following:
1. Disable and reenable the port.
Watch the event log. Stop here if the software entity recovers.
2. Reset the slot.
Watch the event log. Stop here if the software entity recovers.
3. Press the Reset button on the front panel for no more than one second.
This initiates a warm-start procedure, which will keep the log intact.
Watch the event log. Stop here if the software entity recovers.
4. Save the log to a file and use FTP or TFTP to transfer it to the Bay
Networks host. Or, set the router up for modem access so that Bay
Networks can dial in and look at it.
Go to Chapter 8 for instructions.
5. Call the Bay Networks Technical Solutions Center to report the problem.
Caution: Avoid using the diags command to boot a router after it has gone
down. If you do, or if you remove and reinstall power, the diagnostics software
overwrites the log. This prevents you from accessing the log to determine the
cause of the problem.