Site Manager Parameters
117355-D Rev 00
A-33
Parameter: Multiline Threshold Bandwidth
Path: Configuration Manager > XCVR, FDDI, HSSI, MCT1, or COM connector
configured for RSVP > Edit Connector window > Edit Line Resources
Default: 0
Options: 0 to 214,748,364
Function: Specifies how the first fit algorithm works, providing you set the Multiline
Select Algorithm parameter to First Fit. If you accept the default value, the
Resource Manager uses the simple first fit algorithm. If you select a value
greater than 0, the Resource Manager still uses the first available line with
reservable bandwidth to service requests, but moves to the next available line
after reaching the configured threshold. When all lines are at their thresholds,
the Resource Manager resumes using the simple first fit algorithm.
Instructions: Set this parameter only if you configured the Resource Manager on a multiline
circuit and set the Multiline Select Algorithm parameter to First Fit.
Accept the default or enter a number less than the value of the Reservable
Bandwidth parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.16.2.1.3.1.12
Parameter: Reservation Latency
Path: Configuration Manager > XCVR, FDDI, HSSI, MCT1, or COM connector
configured for RSVP > Edit Connector window > Edit Line Resources
Default: 50
Options: 0 to 214,748,364 ms
Function: Specifies the maximum latency for a reserved flow packet, limiting the amount
of unreserved data that the link scheduler can transmit. When the data transmit
ring reaches a size where the time to transmit the data is greater than the value
of this parameter, no more unreserved data will be queued.
Instructions: Reduce the value of this parameter to obtain better delay characteristics for
reserved flows, but note that overall throughput may decrease. Increase the
default value to improve throughput, but note that reserved-flow delays may
increase.
MIB Object ID: 1.3.6.1.4.1.18.3.5.16.2.1.3.1.13