Configuring Frame Relay Services
3-28
117376-C Rev. 00
Using Site Manager
You can enable congestion control for the interface, and you can also customize
values for individual PVCs.
To enable congestion control for the interface
:
To customize congestion control for individual PVCs:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Interfaces
. The Frame Relay Interfaces window
opens.
4. Set the following parameters, using
Help
or the parameter descriptions that begin
on page A-9:
• Congestion Control
• Congestion Timer
• Congestion Counter
•
Congestion Method
(applies only
when you enable traffic shaping)
5. Edit other parameters if you want, and
click on
Apply
.
6. Click on
Done
. You return to the main Configuration
Manager window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Services
. The Frame Relay Service List window
opens.