Customizing Frame Relay
117376-C Rev. 00
3-49
For example:
box; serial/1/2; frame-relay/1/2; lapf/1/2
2.
Enter the
window-size
command and the value you want to use.
window-size
<integer>
<integer>
is the number of outstanding frames allowed. Legal values are 1 to
127. The default is 7.
For example, the following command line sets a window size of 45:
lapf/3/2# window-size 45
lapf/3/2#
Using Site Manager
To edit LAPF parameters
:
Site Manager Procedure
You do this System responds
1. Click on the
Protocols
menu in the
Configuration Manager menu bar.
The Protocols menu opens.
2. Click on
Frame Relay
. The Frame Relay menu opens.
3. Click on
Interfaces
. The Frame Relay Interface List window
opens.
4. Click on the
LAPF
button. The Frame Relay LAPF Parameters
window opens.
5. Edit the following parameters. Use
Help
or
the parameter descriptions in Appendix A
as a guide.
•Enable
• Station Type
• Action Initiate
• T200, Base Timer
• T203, Idle Timer
• N200 Max Retries
• N201, Max Frame Size
• K, Max Window Size
6. When you are finished, click on
OK
. You return to the Frame Relay Interface
List window.
7. Click on
Done
. You return to the main Configuration
Manager window.
Comentarios a estos manuales