Customizing Frame Relay
117376-C Rev. 00
3-15
To add more than one PVC:
1.
Navigate to the service record to which you want to add PVCs.
For example:
box; serial/1/2; frame-relay/1/2; service/4.0.32
2.
Enter the
pvc
command and DLCI number in this format:
pvc
<DLCI number>
; pvc
<DLCI number>
; pvc
<DLCI number>
; ...
For example, the following command line creates PVCs with DLCI numbers
20, 21, 22, 23, and 24:
service/boston# pvc 20; pvc 21; pvc 22; pvc 23; pvc 24;
pvc/3/2/24#
Note that the working context is now that of the PVC you made last.
Using Site Manager
You can add PVCs either individually, or in a range. If you want to add one PVC,
enter one DLCI number. If you want to add several PVCs, enter the appropriate
range of DLCI numbers in the format < lowest DLCI number> - < highest DLCI
number>. To add PVCs:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Services
. The Frame Relay Service List window
opens.
4. Click on
PVCs
. The Frame Relay PVC List window
opens.
5. Click on
Add
. The Frame Relay PVC Add window
opens.
Comentarios a estos manuales