For example, the following command line sets a maximum of 200 SVCs:
signalling/3/2# maximum-svcs 200
signalling/3/2#
Setup Timer
Setup timer indicates the number of seconds allowed from the time the router
sends a setup message to the called subscriber and receives a connect or call
proceeding message from the called subscriber. If a timeout occurs, the router
retransmits the setup message and restarts the timer. If the timer expires a second
time, the call is cleared. To set the setup timer:
1.
Navigate to the signaling prompt.
For example:
box; serial/1/2; frame-relay/1/2; signalling/1/2
2.
Enter the
setup-timer
command and the value you want to use.
setup-timer
<integer>
<integer>
is the number of seconds allowed. Legal values are 2 to 90 seconds.
The default is 4.
For example, the following command line sets a timer of 10 seconds:
signalling/3/2# setup-timer 10
signalling/3/2#
Disconnect Timer
Disconnect timer indicates the number of seconds allowed from the time the
router sends a disconnect message and receives a release message back. If a
timeout occurs, the router sends a release message and enters the release request
state. The timer is not restarted. To set the disconnect timer:
1.
Navigate to the signaling prompt.
For example:
box; serial/1/2; frame-relay/1/2; signalling/1/2
2.
Enter the
disconnect-timer
command and the value you want to use.
disconnect-timer
<integer>