Monitoring Frame Relay Using BCC show Commands
117376-C Rev. 00
C-25
signalling transmit
Displays signalling transmit statistics for frame relay interfaces. This command
allows for the following command filter and filter argument:
The output contains the following information:
-interface
<name>
Displays only SVCs configured on the specified interface.
Interface Interface on which the frame relay SVC resides.
Setup Indicates the number of seconds allowed from the time the
router sends a setup message to the called subscriber and
receives a connect or call proceeding message from the
called subscriber.
Call Proceeding Indicates the number of seconds allowed from the time the
router receives a call proceeding message to the time the
router receives a connect or disconnect message.
Connect Message sent by the called user to the network and by the
network to the calling user to indicate call acceptance by the
called user.
Disconnect Indicates the number of seconds allowed from the time the
router sends a disconnect message and receives a release
message back.
Release Indicates the number of seconds allowed for a call clearing
initiated by the other end of the connection or when the
disconnect timer expires.
Release Complete Indicates that the network returns a release complete
message to the subscriber in response to a release
message sent from the subscriber.
Status Message sent by the user or network in response to a
status enquiry or to report error conditions.
Unnumbered Frames Sent Number of unnumbered acknowledgment frames (UAs)
sent over SVCs to a subscriber or router.
Status Enquiry A message sent by the user or network to solicit a status
message.