Customizing Frame Relay
117376-C Rev. 00
3-59
If you enable congestion control, all SVCs on the interface use congestion control
and the values you specify for the congestion timer and congestion counter, unless
you configure SVCs individually and either disable this feature or select other
values for the congestion control attributes and parameters.
You can use either the BCC or Site Manager to control congestion for SVCs.
Using the BCC
You can use the BCC to configure congestion control for an interface, or for
individual SVCs.
Configuring Congestion Control for an Interface
You can edit the following attributes in the BCC:
Congestion Control
Congestion Timer
Congestion Counter
Congestion Method
Congestion Control
1.
Navigate to the frame-relay prompt.
For example:
box; serial/1/2; frame-relay/1/2
2.
Enter the
congestion-control
command and the value
enabled
:
congestion-control
<enabled>
For example, the following command line enables congestion control for this
frame relay interface:
frame-relay/1/2# congestion-control enabled
frame-relay/1/2#