For example, the following command line sets a congestion timer
of 2.5 seconds:
frame-relay/1/2# congestion-timer 2.5
frame-relay/1/2#
Congestion Counter
To change the value for the congestion counter:
1.
Navigate to the prompt for the interface that you want to edit.
For example:
box; serial/1/2; frame-relay/1/2
2.
Enter the
congestion-counter
command and the value you want the
interface to use:
congestion-counter
<integer>
<integer>
is the maximum number of congestion notifications the router can
receive during the Congestion Timer period before it stops transmitting data.
Legal counter values are 1 to 500 notifications. The default is 20.
For example, the following command line sets a congestion counter
of 30 notifications:
frame-relay/1/2# congestion-counter 30