Configuring Frame Relay Services
3-54
117376-C Rev. 00
2.
Enter the
status-enquiry-retry
command and the integer value you want
to use.
status-enquiry-retry
<integer>
<integer>
is the number of retries. Legal values are 1 to 20 retries.
The default is 4.
For example, the following command line sets a value of 7 retries:
signalling/3/2# status-enquiry-retry 7
signalling/3/2#
Using Site Manager
To edit signaling parameters
:
Site Manager Procedure
You do this System responds
1. Click on the
Protocols
menu in the
Configuration Manager menu bar.
The Protocols menu opens.
2. Click on
Frame Relay
. The Frame Relay menu opens.
3. Click on
Interfaces
. The Frame Relay Interface List window
opens.
4. Click on the
Signaling
button. The Frame Relay Signaling Parameter
window opens.
5. Edit the following parameters. Use
Help
or
the parameters descriptions that begin on
page A-18.
• Signaling Control
• Max SVCs
• T303, Setup Message Timer
• T305, Disconnect Timer
• T308, Release Timer
• T310, Call Proceding Timer
• T322, Status Enq Retry Timer
• N322, Status Enq Retry Max
6. When you are finished, click on
OK
. You return to the Frame Relay Interface
List window.
7. Click on
Done
. You return to the main Configuration
Manager window.