Monitoring Frame Relay Using BCC show Commands
117376-C Rev. 00
C-17
vcs [-dlci
<dlci>
[-interface
<name>
] [-service
<name>
]
[-type {pvc
|
dynamic-pvc
|
svc}]
Displays inbound and outbound statistics for frame relay VCs. This command
allows for the following command filters and filter arguments:
The output contains the following information:
-dlci
<dlci>
Displays only VCs with the specified DLCI.
-interface
<name>
Displays only VCs configured on the specified
interface.
-service
<name>
Displays only VCs on the specified service.
-type
{
pvc | dynamic-pvc |
svc
}
Displays information about only the type of VC
configured:
•
pvc
-- shows only frame relay VCs that are
statically configured PVCs.
•
dynamic- pvc
-- shows only VCs that are
dynamically learned PVCs.
•
svc
-- shows only VCs that are SVCs.
Interface Interface on which the frame relay VC resides.
DLCI Specifies the PVC identification number that the frame relay
network uses to direct data.
Inbound Frames Total number of frames that the interface received.
Inbound Drops Total number of outbound frames dropped because the VC is
inactive.
Outbound Frames Total number of frames that the router sent out on this interface.
Outbound Discard Total number of frames dropped because the VC is inactive.
FECN Number of outbound forward explicit congestion notifications.
BECN Number of outbound backward explicit congestion notifications.
Comentarios a estos manuales