Customizing Frame Relay
117376-C Rev. 00
3-61
For example, the following command line sets a congestion counter
of 30 notifications:
frame-relay/1/2# congestion-counter 30
frame-relay/1/2#
Congestion Method
To change the value for the congestion method:
1.
Navigate to the prompt for the interface that you want to edit.
For example:
box; serial/1/2; frame-relay/1/2
2.
Enter the
congestion-method
command and the value you want the
interface to use:
congestion-method
<value>
Legal values are:
throttle-then-shutdown
shutdown
(the default)
throttle
For example, the following command line sets a congestion method
of throttle:
frame-relay/1/2# congestion-method throttle
frame-relay/1/2#
Configuring Congestion Control for Individual SVC Options
To configure congestion control for an SVC:
Congestion Control
1.
Navigate to the prompt for the SVC option you want to edit.
For example:
serial/3/2; frame-relay/3/2; service/8.0.32; svc-options/toronto
2.
Enter the
congestion-control
command and the value
enabled
:
congestion-control enabled