Starting Dial Services Using Site Manager
308621-14.00 Rev 00
2-11
Configuring PRI Lines
PRI lines are available only on the ASN, BCN
®
, and BLN hardware platforms
using the following link modules:
• Single or Dual Port Multichannel T1 Link Module (BLN and BCN)
• Dual Port Multichannel T1 Net Module (ASN)
• 120-ohm Single Port MCE1-II Link Module (BLN and BCN)
• 120-ohm Single or Dual Port MCE1-II Net Module (ASN)
• QMCT1 Link Module (BLN and BCN)
To configure PRI lines, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on an MCT1 or MCE1 connector.
The Port Application window opens.
2. Set the
Port Application Mode
parameter
to
PRI
and click on
OK
. Click on
Help
or
see the parameter description on
page A-18.
You return to the Configuration Manager
window.
3. Repeat steps 1 and 2 for each PRI line
that you want in the pool.
The Clock Parameters window opens.
The clock parameters define the timing
sources that apply to all connectors and
DS0 timeslots supported by the MCT1
and MCE1 link modules.
4. Click on
OK
. The MCT1 or MCE1 Port Parameters
window opens.
The port parameters apply to each of the
24 DS0 channels for MCT1 ports or 31
DS0 channels for MCE1 ports.
(continued)