Configuring Dial Services
3-14
308621-14.00 Rev 00
Configuring PRI Lines
PRI lines are available only on the ASN, BCN, and BLN platforms using the
following link modules:
• Single or Dual Port Multichannel T1 Link Module (BLN and BCN)
• Dual Port Multichannel T1 Net Module (ASN)
• 120-ohm Single Port MCE1-II Link Module (BLN and BCN)
• 120-ohm Single or Dual Port MCE1-II Net Module (ASN)
• QMCT1 Link Module (BLN and BCN)
To configure PRI lines, create the physical interface for the backup PRI interface
by entering:
mct1
<
slot/module/connector
>;
pri
or
mce1
<
slot/module/connector
>;
pri
module
is only required for the ASN router.
For example:
box#
mct1 3/1; pri
For more information about MCT1 and MCE1 parameters, see Configuring WAN
Line Services.
Go to “Designating an Interface
As a Dial Object” on page 3-14.
Designating an Interface As a Dial Object
Designating an interface as a dial object tells the router that it can use the interface
as a dial line in a line pool.
For dial backup lines, the
dial
command also configures the default layer 2
protocol, PPP.