Configuration Examples
308621-14.00 Rev 00
B-15
Configuration of Routers 1 and 2
To create the dial-on-demand configuration in Figure B-3 on page B-14, configure
routers 1 and 2 according to the instructions in the following sections:
• P
ort Application Mode Configuration on page B-15
• Demand Pool Configuration on page B-16
• Demand Circuit Configuration on page B-17
• Outgoing Phone List Configuration on page B-18
• Protocol Configuration on page B-19
• Caller Resolution Table Configuration on page B-19
• Local Phone Number Configuration on page B-20
Port Application Mode Configuration
Begin by setting the Port Application Mode parameter for interfaces on routers 1
and 2. These interfaces will become part of the demand pool.
Site Manager Procedure
You do this System responds
1. Router 1: In the Configuration Manager
window, choose the
MCT1-2
connector on
the MCT1 link module.
Router 2: In the Configuration Manager
window, choose the
ISDN1
connector on
the ISDN/BRI net module.
The Port Application window opens.
2. Set the
Port Application Mode
as follows
then click on
OK
:
• Router 1:
PRI
• Router 2:
Dialup -
2B+D
(default)
For router 1 (the PRI interface), the Clock
Parameters window opens.
3. For router 1 only, set the
Primary Clock
parameter to
Port 2 Ext Loop
then click
on
OK
.
The Port Parameters window opens.
4. Accept the default values for all
parameters by clicking on
OK
.
The PRI Logical Lines timeslots window
opens.
(continued)