Customizing Backup Circuits
308621-14.00 Rev 00
13-11
Using Site Manager
To edit the backup mode, complete the following tasks:
Modifying PPP Authentication Information
To configure PPP authentication, you can use CHAP or PAP. You configured
CHAP authentication, the default authentication protocol, in Chapter 2, “Starting
Dial Services Using Site Manager” or Chapter 3 “Starting Dial Services Using the
BCC.”
For more information about CHAP and PAP, see Chapter 5, “Implementation
Notes for All Dial Services.
Using the BCC
Changing the Authentication Protocol
CHAP is the default authentication protocol. To change the authentication
protocol that the router uses, navigate to the dial prompt and enter:
authentication-protocol
<
protocol
>
protocol
can be pap, chap, or none.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuit
s. The Backup Circuits menu opens.
3. Choose
PPP
. The Primary Circuit Definition window
opens.
4. Select the
Backup Mode
parameter. Click
on
Help
or see the parameter description
on page A-70.
5. Click on
Done
. You return to the Configuration Manager
window.