Vista de pagina 402
Site Manager Parameters
308621-14.00 Rev 00
A-51
Circuit Duration Parameters (Demand and Dial Backup)
The circuit duration parameters determine how long the connection remains
active, not the circuits availability. These parameters are located in each service’s
circuit configuration window.
Parameter: Maximum Up Time
Path: Demand Circuits: Dialup > Demand Circuits > Demand Pools >
PPP or FR Circuits > PPP or FR Demand Circuits
Backup Circuits: Dialup > Backup Circuits > PPP or Frame Relay > Primary
Circuit Definition or FR Primary Interface Definition
Default: 60 minutes
Options: 1 to 999,999 minutes
Function: Specifies the maximum duration of a call for a continuous period of time. This
parameter value ensures that the connection is not up longer than necessary.
For example, you may configure the circuits availability (via the Start and End
time parameters) from 9:00 a.m. to 5:00 p.m. Then configure this parameter for
60 minutes. If the connection comes up at 10:00 a.m., the router keeps the
circuit active until 11:00 a.m. Then, the router invokes the Max UpTime
Termination parameter to deactivate the circuit.
Instructions: Enter the maximum active time for a call during a continuous period of time.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.10