Site Manager Parameters
308621-14.00 Rev 00
A-33
Parameter: BRI T4 Timer
Path: ISDN Connector > ISDN Dialup > Edit D Chan >
BRI Interface Configuration
Default: 750 milliseconds
Options: 500 to 1000 milliseconds
Function: Indicates the amount of time the router waits for the line to recover from a
deactivated state. This timer prevents brief, minor disturbances on a noisy line
from forcing the router to deactivate the circuit. Instead, the router waits to see
if the line recovers within the T4 timer period. This enables the router to
suppress minor line problems from the upper-layer protocols.
Instructions: Enter a time limit that the router waits for the line to recover before it
deactivates the circuit. If your line is noisy, enter the maximum time for the
router to wait for the line to reactivate.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.8.9.1.15