Avaya Configuring Dial Services Manual de usuario Pagina 272

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 552
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 271
Configuring Dial Services
12-44
308621-14.00 Rev 00
To configure the delay back to the primary circuit, navigate to the schedule prompt
and enter:
schedule-standby-failback-time <
integer
>
integer
is a number from 0 to 1439 minutes. The default is 0.
For example, to delay the return to the primary circuit for an hour, enter:
schedule/to-boston/weekday/1000/2100#
schedule-standby-failback-time 60
Using Site Manager
To configure a standby circuit’s schedule:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Demand Circuits
. The Demand Pools window opens.
3. Click on
PPP Circuits
or
FR Circuits
. The PPP Demand Circuits window or the
FR Demand Circuits window opens.
4. Click on
Schedule
. The Circuit Time of Day Schedule window
(PPP) or the Pool Availability window
(frame relay) opens.
5. Set the following parameters:
TimeOfDay Failback Mode
Failback Time (min.)
Click on
Help
or see the parameter
descriptions beginning on page A-60.
6. Click on
Apply
, then click on
Done
. You return to the appropriate demand
circuits window.
7. Click on
Done
. You return to the Demand Pools window.
8. Click on
Done
. You return to the Configuration Manager
window.
Vista de pagina 271
1 2 ... 267 268 269 270 271 272 273 274 275 276 277 ... 551 552

Comentarios a estos manuales

Sin comentarios