Table 12-3 shows the time of day schedules for standby circuit 1.
Example 1: Failback Times That Overlap
If you schedule the standby circuit to terminate before the failback time expires,
the router still terminates the standby circuit. The router does not wait for the
primary circuit to recover. There is no circuit available until the primary circuit
reactivates or the standby circuit is available again (see “Example 2: Failback
Time Results in No Available Circuit”).
Table 12-3. Time of Day Schedules for Standby Circuit 1
Time of Day Schedule 1 Time of Day Schedule 2 Time of Day Schedule 3
Start Time: 8 a.m.
End Time: 11 a.m.
Start Time: 11 a.m.
End Time: 5 p.m.
Start Time: 7 p.m.
End Time: 11 p.m.
Failback Time: 60 minutes Failback Time: 10 minutes Failback Time: 10 minutes
7:00 a.m.
The primary circuit fails.
8:00 a.m.
The standby circuit becomes available.
10:30 a.m.
The primary circuit recovers and the failback timer starts counting
down from 60 minutes. Data is still traveling over the standby circuit.
11:00 a.m.
Since 10:30 a.m., 30 minutes of failback time have elapsed for time
of day schedule 1, but time of day schedule 2 is now active. This new
schedule has a failback time of 10 minutes, which supersedes the
previous failback time of 60 minutes. Because 10 minutes have
passed, data traffic returns to the primary circuit.