Configuring Ethernet, FDDI, and Token Ring Services
A-4 117344-A Rev. A
Parameter: BofL Enable
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters
Default: Enable
Options: Enable
| Disable
Function: Enables or disables BofL polling.
When you set both this parameter and the LLC Data Enable parameter to
Enable, the router disables the LLC interface after the time you specify using
the BofL Timeout parameter if the link becomes unavailable.
When you set this parameter to Disable, the router disables the LLC interface
immediately after the link becomes unavailable.
Instructions: Set to Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.4.1.7
Parameter: BofL Timeout
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters
Default: 3
Options: 1 to 60 seconds
Function: When BofL is enabled and the link becomes unavailable, this parameter
specifies the time Site Manager waits before disabling the LLC interface.
Instructions: Accept the default value, 3 seconds, or specify a new value. Be sure to set the
BofL Enable parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.4.1.8
Comentarios a estos manuales