Configuring Ethernet, FDDI, and Token Ring Services
3-6 117344-A Rev. A
Using the BCC
To change the interval of BofL messages, access an existing FDDI line service
and enter:
bofl-timeout
<integer>
<integer>
is the timeout value expressed in seconds. You can enter any integer
value between 0 and 3600.
For example, to change the BofL interval to 10:
box> fddi slot 11 connector 1
fddi/11/1> bofl-timeout 10
Using Site Manager
Complete the tasks in the following table to change the interval of BofL messages.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a FDDI Connector.
The Edit Connector window opens.
2. Choose Edit Line. The Edit FDDI Parameters window
opens.
3. Set the BofL Timeout parameter. Click on
Help or see the parameter description on
page A-4.
4. Click on OK. Site Manager returns you to the Edit
Connector window.
5. Click on Done. Site Manager returns you to the
Configuration Manager window.