Configuring Ethernet, FDDI, and Token Ring Services
3-24 117344-A Rev. A
Specifying the LER Alarm
The LER alarm rate is an estimate at which a link connection generates an alarm.
The LER alarm ranges from 10
-4
to 10
-15
and is reported as the absolute value of
the base 10 logarithm of the estimate. By default, the LER alarm is 10
-8
.
You can specify the LER alarm rate only by using Site Manager.
Using Site Manager
Complete the tasks in the following table to set the LER alarm rate.
6. Click on OK. Site Manager returns you to the FDDI
Advanced Attributes window.
7. Click on Done. Site Manager returns you to the Edit
Connector window.
8. Click on Done. Site Manager returns you to the
Configuration Manager window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a FDDI Connector.
The Edit Connector window opens.
2. Choose Edit Line. The Edit FDDI Parameters window
opens.
3. Choose Expert. The FDDI Advanced Attributes window
opens.
4. Choose Port Attributes. The FDDI Port Attributes window opens.
5. Set the LER Alarm parameter. Click on
Help or see the parameter description on
page A-10.
6. Click on OK. Site Manager returns you to the FDDI
Advanced Attributes window.
(continued)
Site Manager Procedure
(continued)
You do this System responds