Specifying the Propagation Expiration Time
A trace is a diagnostic function that isolates a fault on the ring. By default, the
maximum propagation time for a trace on a FDDI topology is 7 seconds. You can
set the propagation expiration time to a value from 6001 to 256000 milliseconds
(ms).
Using the BCC
To set the propagation expiration time, access an existing FDDI line service and
enter:
token-rotation-time
<integer>
<integer>
is the propagation expiration time expressed in seconds.
For example, to set the propagation expiration time to 10:
box> fddi slot 11 connector 1
fddi/11/1> token-rotation-time 10
Using Site Manager
Complete the tasks in the following table to set the propagation expiration time.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose a FDDI Connector
.
The Edit Connector window opens.
2. Choose Edit Line. The Edit FDDI Parameters window
opens.
3. Choose Expert. The FDDI Advanced Attributes window
opens.
4. Choose SMT Attributes. The FDDI SMT Attributes window opens.
5. Set the Trace Max Expiration (ms)
parameter. Click on Help or see the
parameter description on page A-7.
6. Click on OK. Site Manager returns you to the FDDI
Advanced Attributes window.