Configuring AN and ANH Features
6-13
DCM Global Parameter Descriptions
Parameter: Enable/Disable
Default: ENABLE
Options: ENABLE
| DISABLE
Function: Enables or disables DCMMW (the DCM software subsystem), and
therefore the DCM board.
Instructions: To enable the DCM board, select ENABLE. To disable the DCM board,
select DISABLE. Use this parameter to reboot the DCM board by
enabling, then disabling DCMMW.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.16.1.2
Parameter: Image Name
Default: None, but you must specify an image name when the Boot Option
parameter is set to DOWNLOAD.
Options: An ASCII text string, no more than 255 characters
Function: Specifies the pathname of a DCM boot image in the ANH file system. The
image name must be a fully qualified filename, including both volume
and filename.
Instructions: Enter the volume and filename for the image you want the DCM board to
boot, using the form <volume_number:filename>; for example,
1:dcm_image.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.16.1.3