Site Manager Line Services Parameters
114078 Rev. A A-55
Synchronous Line Parameters
You access the synchronous line parameters from the Configuration Manager.
Parameter: Enable
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: Enable
Options: Enable
| Disable
Function: Enables or disables this synchronous line.
Instructions: Set this parameter to either Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.2
Parameter: BofL
Path: COM Connector > Edit Line > Edit Sync Parameters
Default: Enable
Options: Enable
| Disable
Function: Enables the transmission of proprietary BofL messages over a point-to-point
connection between the local router and a remote peer.
Instructions: Set to Enable or Disable, depending on whether you want to transmit BofL
messages over this synchronous interface. If you enable BofL locally, the
remote peer must also be configured to enable BofL.
We recommend that you enable BofL for point-to-point connections between
Bay Networks peers. However, if such a connection is accomplished through a
wide-area transport service such as Frame Relay, X.25, or SMDS, you must
disable BofL.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.7