Common Configuration
# P0602477 Ver: 3.1.11 Page 203
Alarm Filtering
Typically alarm filtering is performed through details stipulated at the PeriView
Alarm Viewer; however, this still requires that all alarms generated be forwarded to
the viewer. In cases where alarm production is excessive, traffic overhead can place
an undue burden on the system, thereby degrading overall performance. In order to
avoid a situation like this, alarm filtering has been instituted at a lower (daemon) level,
allowing for a boost in system performance and/or distinct customizing to meet site
and customer needs.
Filtering can be accomplished through either the alarmd or alarmf daemon, or
both (alarmf can also be run as a utility - see the latter portion of “Notation
Functionality” on page 207). Generally in a single or limited node environment
filtering through alarmd is sufficient. However in situations where there are many
nodes in a network, each running an instance of alarmd, or where alarm traffic has
become substantial, further consolidation of filtered alarms can be performed by
alarmf. Depending on system needs and configuration, there can be present either
one or multiple instances of alarmf. This can reduce the overall number of alarms
ultimately delivered to the viewers, and depending on the actions stipulated by the
user, can reduce the frequency with which system operators or administrators are
required to interact with the system. Any number of filtering criteria can be applied in
situations where multiple instances of the daemons exist, and filtered and unfiltered
daemons can be combined as well. Additional details on these scenarios are provided
in the sections that follow, and at “Filtering Examples” on page 213.
For information on the PeriView Alarm Viewer, please see the PeriView Reference
Manual. For additional information concerning the alarm daemons, see VOS
Alarm Filtering Conceptual Diagram
Single Node
Environment
alarmd
Filter Set
Producer (VMM,
CCM, SRP, etc)
PeriView
Alarm Viewer
Multi Node
Environment
(Combined
Assessment)
alarmf
Filter Set
PeriView
Alarm Viewer
alarmd
Filter Set
Producer (VMM,
CCM, SRP, etc)
alarmd
Producer (VMM,
CCM, SRP, etc)
alarmd
Producer (VMM,
CCM, SRP, etc)
(Alarms are
filtered twice)
(Alarms are
filtered once)
(Alarms are unfiltered)
(With alarmf selected in the Comp: field of the Viewer)