Troubleshooting Routers
C-4
308656-14.00 Rev 00
3: Stop Capture when Transmit Filter Two is Matched
4: No Transmit Trigger
Current value for Transmit Trigger is 4
Press return for current value or enter new value: 4
Packet Capture Receive Capture Filter Configuration
---------------------------------------------------
Receive Filter One Type Options
-------------------------------
1: Capture
3: Not Used
Current value for Receive Filter One Type is 3
Press return for current value or enter new value: 1
Current value for Receive Filter One Offset is 0
Press return for current value or enter new value:
Receive Filter One Reference Options
------------------------------------
1: Mac
2: Data Link
3: Multicast
Current value for Receive Filter One Reference is 1
Press return for current value or enter new value:
Current value for Receive Filter One Size is 0
Press return for current value or enter new value: 6
Current value for Receive Filter One Match is
0x(nil)
Press return for current value or enter new value: 0x0000a200000c
Receive Filter Two Type Options
-------------------------------
1: Capture
3: Not Used
Current value for Receive Filter Two Type is 3
Press return for current value or enter new value:
Packet Capture Transmit Capture Filter Configuration
----------------------------------------------------
Transmit Filter One Type Options
--------------------------------
1: Capture
3: Not Used
Comentarios a estos manuales