Reading the Event Log
308656-14.00 Rev 00
A-37
The following command displays the new port status:
[3:1]$ show ds1e1 port
DS1E1 Port Status:
------------------
2 entries in table.
If you configure the primary clock source as the port 2 loop and the secondary
clock source as the port 1 loop, both clocks fail and the following messages appear
in the log:
# 62: mm/dd/yy 10:44:50.734 WARNING SLOT 3 DS1E1 Code: 14
Connector COM2 Loss of signal failure.
# 63: mm/dd/yy 10:44:50.734 INFO SLOT 3 DS1E1 Code: 23
Primary and Sec clocks unoperational - Switching to Internal Clock
Source.
The following message appears if you mismatch the line coding. In this example,
the line coding of one side is AMI and the other is B8ZS (binary 8 zero
substitution).
# 234: mm/dd/yy 09:01:43.121 INFO SLOT 2 DS1E1 Code: 24
Connector COM1 B8ZS code received on port configured for AMI.
If you set the line type to ESF, many messages indicate bipolar violations on the
side configured for AMI.
Ti prompt> show ds1e1 fdl ansi1
DS1E1 Facility Data Link (FDL) errors (first half) - ANSI-403 mode:
------------------
Slot Conn State MTU Loopback
State
Accept
Loopback
BERT
Mode
Line
Type
Line
Coding
FDL
Type
FDL
Addr
4 1 Red Alarm 1600 No Loop Enabled Off ESF AMI AT&T BY
5 2 Red Alarm 1600 No Loop Enabled Off ESF AMI AT&T BY
Slot Conn CRC
Counts
BPV
Counts
OOF
Counts
FE
Counts
ES
Counts
2 1 65535 964252 0 0 1675