Configuring WAN Line Services
4-4
117345-B Rev. 00
The Transmit Clock Source parameter is set to Slave by default. Note that there
can be only one clock source on a DDS line.
See the Transmit Clock Source parameter on page A-8
for information.
Enabling or Disabling the 64K Transmit Monitor
This parameter is valid only when the Option Mode parameter is set to
CC-64KBPS. When enabled, the 64K Transmit Monitor parameter suppresses
data to prevent unintended duplication of a network control code. For example,
user data that includes the text of a loopback control code could place the remote
end of the connection in a loop.
The 64K Transmit Monitor parameter is disabled by default. Keep the parameter
disabled to allow all data; select Enabled to monitor and suppress user data.
See the 64K Transmit Monitor parameter on page A-9
for information.
Configuring V.54 Loopback Tests
You can use a set of supported loopback modes for testing both the router’s
DSU/CSU interface and the network/Telco circuit to the router. This section
provides information about the following:
Section Page
Configuring the V.54 Loopback Test
4-6
Configuring the V.54 Loopback Timer 4-7
Loopback Test Modes 4-7